![Newton Security T-DAR T1000 Installation And Operation Manual Download Page 31](http://html1.mh-extra.com/html/newton-security/t-dar-t1000/t-dar-t1000_installation-and-operation-manual_1680906031.webp)
31
Stereo Tracking Head Placement chart
Distance from the center of the
Stereo Camera Head to the door
(A)
Distance from the front of the
Stereo Camera Head to the floor
(B)
Type of
Camera
Inches
CM
Inches
M
*
*
84 to 96*
2.1 to 2.44*
*
12-20
31-51
96 (8’)
2.44
DC 219
Stereo
Camera Head
12-20
31-51
100
2.54
DC 219
Stereo
Camera Head
12-20
31-51
104
2.64
DC 219
Stereo
Camera Head
09-20
23-51
107
2.71
DC 219
Stereo
Camera Head
9-21
23-53
108 (9’)
2.74
DC 225
Stereo
Camera Head
9-21
23-53
114
2.95
DC 225
Stereo
Camera Head
9-21
23-53
120 (10’)
3.05
DC 225
Stereo
Camera Head
12-21
23-53
121
3.07
DC 229
Stereo
Camera Head
12-21
23-53
126
3.20
DC 229
Stereo
Camera Head
12-21
23-53
132 (11’)
3.37
DC 229
Stereo
Camera Head
*
*
Over 132
(11”)*
Over 3.37*
*
* Non-standard Installation. Consult factory for assistance
(Examples of non-standard installations are any installation under 8 FT (2.44M) or
over 11 FT (3.37M))
Please see figure 14 for Installation Guide
Summary of Contents for T-DAR T1000
Page 12: ...12 Figure 2 T DAR Control Unit CAD...
Page 14: ...14 Figure 4 T DAR Annunciator CAD...
Page 16: ...16 Figure 6 T DAR Stereo Tracking Head...
Page 18: ...18 F igure 8 T DAR Door Encoder...
Page 20: ...20 Figure 10 T DAR Event Camera...
Page 22: ...22 Figure 12 T DAR Cable Extender Amplifier CAD...
Page 37: ...37 Figure 16 Typical Dry Configuration...
Page 89: ...89...