Appendix B — Troubleshooting
B - 7
WARNING
Power-down all equipment before cleaning.
CAUTION
Do not expose connectors, fans, LEDs, or switches to alcohol or water.
Place the power supply board on a flat surface, and rotate the notch in the
fuseholder cover until it releases (see Figure B.2-4).
N97120A
F1
FUSEHOLDER
Figure B.2-4 — Power Supply Board Fuse Replacement
Remove and inspect the fuse. Replace as needed with 3.15A, 250V fuse
(Schurter part number 70353).
Re-install the power supply board.
Re-install the rear power line board, guiding the white plastic plunger back
into the power switch cut-out at the front of the UniDrive.
Re-attach the black plastic cap to the end of the plunger.
Re-connect and power-up the system to verify that the problem has been
corrected.
B.3 Cleaning
Clean the exterior metallic surfaces of the UniDrive6000 with water and a
clean, lint-free cloth. Clean external cable surfaces with alcohol, using a
clean, lint-free cloth.