136
Check Character Verification
A check character is optional for Industrial 25 and can be added as the last character. It is a calculated value used to verify
the integrity of the data.
Disable:
The scanner transmits Industrial 25 barcodes as is.
Do Not Transmit Check Character After Verification:
The scanner checks the integrity of all Industrial 25 barcodes
to verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted
except the last digit, whereas those failing it will not be transmitted.
Transmit Check Character After Verification:
The scanner checks the integrity of all Industrial 25 barcodes to verify
that the data complies with the check character algorithm. Barcodes passing the check will be transmitted, whereas
those failing it will not be transmitted.
@L25CHK0
** Disable
@L25CHK1
Do Not Transmit Check Character After Verification
@L25CHK2
Transmit Check Character After Verification
If the
Do Not Transmit Check Character After Verification
option is enabled, Industrial 25 barcodes
with a length that is less than the configured minimum length after having the check character excluded
will not be decoded. (For example, when the
Do Not Transmit Check Character After Verification
option is enabled and the minimum length is set to 4, Industrial 25 barcodes with a total length of 4
characters including the check character cannot be read.)
Summary of Contents for NLS-HR42
Page 1: ...NLS HR42 2D Handheld Barcode Scanner User Guide...
Page 23: ...9 Dimensions Left View Front View...
Page 24: ...10 Top View...
Page 48: ...34...
Page 65: ...51 KBWCTY27 UK KBWCTY28 Japan...
Page 79: ...65 KBWPOR8 9ms KBWPOR9 10ms...
Page 115: ...101 FEBSDT70 70ms FEBSDT75 75ms...
Page 116: ...102 Transmit Delay per 12 Characters FEBMEN0 Disable FEBMEN1 Enable...
Page 118: ...104 FEBMDT6 800ms FEBMDT7 900ms...
Page 184: ...170 DMCREC1 Enable Rectangular Barcode DMCREC0 Disable Rectangular Barcode...
Page 242: ...228 Appendix Digit Barcodes 0 9 DIGIT0 0 DIGIT1 1 DIGIT2 2 DIGIT3 3 DIGIT4 4 DIGIT5 5...
Page 243: ...229 DIGIT6 6 DIGIT7 7 DIGIT8 8 DIGIT9 9...
Page 244: ...230 A F DIGITA A DIGITB B DIGITC C DIGITD D DIGITE E DIGITF F...
Page 254: ...240 Terminating Character Suffix Enabled CR 0x0D Max 2 characters...