** Enter Setup
29
Exit Setup
Timeout between Decodes (Same Barcode)
Timeout between Decodes (Same Barcode) can avoid undesired rereading of same barcode in a given
period of time. It is programmable in 100ms increments from 0ms to 12,000ms. When it is set to 12700,
the timeout is infinite. The default setting is 400ms.
Timeout between Decodes (Same Barcode)
Example: Set the timeout between decodes (same barcode) to 1,000ms
1. Scan the
Enter Setup
barcode.
2. Scan the
Timeout between Decodes (Same Barcode)
barcode.
3. Scan the numeric barcodes “1”, “0”, “0” and “0” from the “Digit Barcodes” section in Appendix.
4. Scan the
Save
barcode from the “Save/Cancel Barcodes” section in Appendix.
5. Scan the
Exit Setup
barcode.
Summary of Contents for HR11+ Aringa
Page 1: ...HR11 Aringa 1D Handheld Barcode Scanner User Guide...
Page 4: ......
Page 22: ...10 Dimensions unit mm Side View Front View Top View...
Page 49: ...Enter Setup 37 Exit Setup Good Read Beep Duration Medium 80ms Short 40ms Long 120ms...