** Enter Setup
25
Exit Setup
Blink Mode
Blink Mode:
The scanner automatically activates a decode session. The decode session continues until
the barcode is decoded or the decode session timeout expires (100ms; non-programmable). When a
decode session is completed, the scanner waits until the timeout between decodes expires (default: 1s,
user programmable) and then starts next session. The scanner continues to work in this pattern.
Pressing the trigger can also activate a decode session; holding down the trigger can suspend decode
session.
Blink Mode
Timeout between Decodes
Timeout between Decodes:
This parameter sets the time period between the end of one decode
session and the start of next session. It is programmable in 500ms increments from 0ms to 7,500ms. The
default timeout is 0ms. To program this parameter, scan the
Timeout between Decodes
barcode, the
numeric barcodes and the
Save
barcode.
Timeout between Decodes
Example: Set the timeout between decodes to 1,000ms
1. Scan the
Enter Setup
barcode.
2. Scan the
Timeout between Decodes
barcode.
3. Scan the numeric barcodes “1”, “0”, “0” and “0” from the “Digit Barcodes” section in Appendix.
4. Scan the
Save
barcode from the “Save/Cancel Barcodes” section in Appendix.
5. Scan the
Exit Setup
barcode.