** Enter Setup
159
Exit Setup
EF Insert a delay
Syntax
=
EFnnnn (nnnn: The delay in 5ms increments, up to 9999)
Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position.
This command can only be used with USB HID-KBW.
EF Example: Insert a delay of 1s between the 5
th
and 6
th
character
Send the first 5 characters in a barcode, wait for 1s, then send the rest of the barcode data.
Command string:
F20500EF0200E900
F2 is the “Send a number of characters” command
05 is the number of characters to send
00 is the hex value for a Null character
EF is the “Insert a delay” command
0200 is the delay value (5msX200=1000ms=1s)
E9 is the “Send all but the last characters” command
00 is the number of characters that will not be sent at the end of the message
Summary of Contents for HR11+ Aringa
Page 1: ...HR11 Aringa 1D Handheld Barcode Scanner User Guide...
Page 4: ......
Page 22: ...10 Dimensions unit mm Side View Front View Top View...
Page 49: ...Enter Setup 37 Exit Setup Good Read Beep Duration Medium 80ms Short 40ms Long 120ms...