7 - MAINTENANCE
Fuse and relays in the cab area – Mechanical controls only
1. Remove all the screws
(1)
from the cover panel
(2)
to
expose the fuse and relay blocks.
NOTE:
The fuse and relay identification decal is on the
back side of the cover panel.
2. Remove the fuse panel
(2)
to expose the cab area
fuses and relays
(3)
3. Press both locking tabs
(4)
to release and remove the
cover.
NOTICE:
Only replace fuse and relays with the same
type and amperage rating. Failure to do so may result
in an electrical system failure.
4. Locate and check the problem fuse or relay. If neces-
sary, replace the fuse or relay.
RAIL15SSL0101BA
3
NOTICE:
Avoid water and moisture from entering the fuse
and relay block, make sure that the cover is properly posi-
tioned and fully latched. Failure to do so may allow water
or moisture to enter the power center and possibly result
in an electrical system failure.
5. Align the locking tabs on the fuse block cover and push
down to secure in place. Make sure that the cover is
in proper position and secure.
NOTICE:
Avoid water from entering the power center,
make sure that the fuse panel cover is in the proper posi-
tion and secure. Failure to do so may allow water to enter
the power center and possibly result in an electrical sys-
tem failure.
6. Position the fuse and relay cover so that all sides are
flush or even with the heel kick plate.
7. Hold the fuse and relay panel cover in position.
8. Tighten the screws to secure the cover in position.
RAIL16SSL0032BA
4
RAIL15SSL0355AA
5
7-19
Summary of Contents for 200 Series
Page 60: ...2 SAFETY INFORMATION 2 44 ...
Page 130: ...3 CONTROLS AND INSTRUMENTS 3 70 ...
Page 154: ...5 TRANSPORT OPERATIONS 5 14 ...
Page 184: ...7 MAINTENANCE L213 and L215 machines with Electro Hydraulic EH controls 47946332B 6 7 20 ...
Page 250: ...7 MAINTENANCE 7 86 ...
Page 288: ...10 ACCESSORIES 10 2 ...