7 - MAINTENANCE
8. Fill the cooling system with
NEW HOLLAND AMBRA
ACTIFULL™ OT EXTENDED LIFE COOLANT
until
the coolant level is just to the overflow tube.
9. Install the radiator cap.
10. Fill the coolant reservoir up to the COLD mark.
11. Start the engine and increase the temperature of the
engine coolant. Once the coolant is at operating tem-
perature, stop the engine and allow to cool.
12. Check the coolant level at the reservoir only. DO NOT
remove the radiator cap. Add coolant to the reservoir,
if necessary.
13. Check the hoses, elbows and system for leaks.
BT04H069-01
2
Capacity
L213
15 l
(
4.0 US gal
)
L215, L218, L220
15.6 l
(
4.2 US gal
)
L223, L225, L230, C232, C238
19 l
(
5 US gal
)
C227
17 l
(
4.5 US gal
)
Specifications
NEW HOLLAND AMBRA ACTIFULL™ OT EXTENDED
LIFE COOLANT
NOTICE:
DO NOT mix ethylene glycol coolant with
NEW HOLLAND AMBRA ACTIFULL™ OT EXTENDED LIFE
COOLANT
. See
7-14
for more information.