![NetApp SG100 Hardware Installation And Maintenance Manual Download Page 74](http://html.mh-extra.com/html/netapp/sg100/sg100_hardware-installation-and-maintenance-manual_1669914074.webp)
a. Connect to the DB-9 serial port on the back of the appliance.
b. Use settings
115200 8-N-1
.
c. View the codes printed over the serial terminal.
5. If you are using SOL, perform these steps:
a. Connect to the IPMI SOL using the BMC IP address and login credentials.
ipmitool -I lanplus -H 10.224.3.91 -U root -P calvin sol activate
b. View the codes on the virtual serial terminal.
6. Use the table to look up the codes for your appliance.
Code
Indicates
HI
The master boot script has started.
HP
The system is checking to see if the network interface card (NIC) firmware needs to be updated.
RB
The system is rebooting after applying firmware updates.
FP
The hardware subsystem firmware update checks have been completed. Inter-controller
communication services are starting.
HC
The system is checking for existing StorageGRID installation data.
HO
The StorageGRID appliance is running.
HA
StorageGRID is running.
Related tasks
You can access the BMC interface on the services appliance using the DHCP or static IP address
for the BMC management port.
Viewing error codes for the appliance
If a hardware error occurs when the appliance is booting up, the BMC logs an error code. As
required, you can view these error codes using the BMC interface, and then work with technical
support to resolve the issue.
Before you begin
•
You know how to access the BMC dashboard.
Steps
1. From the BMC dashboard, select BIOS POST Code.
2. Review the information displayed for Current Code and the Previous Code.
If any of the following error codes are shown, work with technical support to resolve the issue.
Code
Indicates
0x0E
Microcode not found
0x0F
Microcode not loaded
0x50
Memory initialization error. Invalid memory type or incompatible memory speed.
0x51
Memory initialization error. SPD reading has failed.
0x52
Memory initialization error. Invalid memory size or memory modules do not match.
0x53
Memory initialization error. No usable memory detected.
0x54
Unspecified memory initialization error
Hardware Installation and Maintenance Guide for SG100 and SG1000 Appliances
74