1. From the StorageGRID Appliance Installer, click Configure Networking > Port Connectivity
Test (nmap).
The Port Connectivity Test page appears.
The port connectivity table lists node types that require TCP connectivity on the Grid Network.
For each node type, the table lists the Grid Network ports that should be accessible to your
appliance.
You can test the connectivity between the appliance ports listed in the table and the other nodes
in your Grid Network.
2. From the Network drop-down, select the network you want to test: Grid, Admin, or Client.
3. Specify a range of IPv4 addresses for the hosts on that network.
For example, you might want to probe the gateway on the network or the primary Admin
Node.
Specify a range using a hyphen, as shown in the example.
4. Enter a TCP port number, a list of ports separated by commas, or a range of ports.
5. Click Test Connectivity.
•
If the selected port-level network connections are valid, the "Port connectivity test passed"
message appears in a green banner. The nmap command output is listed below the banner.