![NetApp SG100 Hardware Installation And Maintenance Manual Download Page 24](http://html.mh-extra.com/html/netapp/sg100/sg100_hardware-installation-and-maintenance-manual_1669914024.webp)
Port
Type of port
Function
3
Admin Network port on the
appliance (labelled P1 in the
figures)
1-GbE (RJ-45)
Attention:
This port
operates only
at 1000
baseT/full
and does not
support 10-
or 100-
megabit
speeds.
Connects the appliance to the Admin
Network for StorageGRID.
Rightmost RJ-45 port on the
appliance
1-GbE (RJ-45)
Attention:
This port
operates only
at 1000
baseT/full
and does not
support 10-
or 100-
megabit
speeds.
•
Can be bonded with management port 1
if you want a redundant connection to
the Admin Network.
•
Can be left disconnected and available
for temporary local access (IP
169.254.0.1).
•
During installation, can be used to
connect the appliance to a service laptop
if DHCP-assigned IP addresses are not
available.
Steps
1. Connect the BMC management port on the appliance to the management network, using an
Ethernet cable.
Although this connection is optional, it is recommended to facilitate support.
2. Connect the network ports on the appliance to the appropriate network switches, using TwinAx
cables or optical cables and transceivers.
Note: The four network ports must use the same link speed. See the following tables for the
equipment required based on your hardware and link speed.
SG100 link speed (GbE)
Required equipment
10
SFP+ transceiver
25
SFP28 transceiver
SG1000 link speed (GbE)
Required equipment
10
QSA and SFP+ transceiver
25
QSA and SFP28 transceiver
40
QSFP+ transceiver
100
QFSP28 transceiver
•
If you plan to use Fixed port bond mode (default), connect the ports to the StorageGRID
Grid and Client Networks, as shown in the table.
Hardware Installation and Maintenance Guide for SG100 and SG1000 Appliances
24
Installing the hardware