Related tasks
You can configure network links for the ports used to connect the appliance to the Grid Network,
the Client Network, and the Admin Network. You can set the link speed as well as the port and
network bond modes.
on page 92
You can change the MTU setting that you assigned when you configured IP addresses for the
appliance node.
Verifying port-level network connections
To ensure that access between the StorageGRID Appliance Installer and other nodes is not
obstructed by firewalls, confirm that the StorageGRID Appliance Installer can connect to a
specific TCP port or set of ports at the specified IP address or range of addresses.
About this task
Using the list of ports provided in the StorageGRID Appliance Installer, you can test the
connectivity between the appliance and the other nodes in your Grid Network.
Additionally, you can test connectivity on the Admin and Client Networks and on UDP ports, such
as those used for external NFS or DNS servers. For a list of these ports, see the port reference in
the StorageGRID networking guidelines.
Note: The Grid Network ports listed in the port connectivity table are valid only for
StorageGRID version 11.5.0. To verify which ports are correct for each node type, you should
always consult the networking guidelines for your version of StorageGRID.
Hardware Installation and Maintenance Guide for SG100 and SG1000 Appliances
44
Configuring StorageGRID connections