29
Zhejiang Neoden Technology Co., Ltd
In XY motion interface, when selecting nozzles No.1-No.6, user should lock the position at first, input a certain height value
and then click the nozzle test to go down to measure whether the pick height is reasonable.(Note: when testing the pick
height in locked interface,the feeder won’t turn on automatically. You can select the component above the edge of the
sheeting to measure.
Place height:
Measuring method: first measure the height from the nozzle to the pcb board. Considering the thickness of the component
itself, press down about 0.1mm or o.2mm. For special component, make appropriate adjustment.
Pick delay: for special components,such as large IC, 0402 resistor and capacitor etc, it’s better to set some long time on
the pick delay to make sure nozzle can pick up them stably.
Place delay: for special components,such as large IC and large capacitor etc, it’s better to set some long time on the
place delay to make sure nozzle can still suck the component stably during the movement to the board.
Move speed: it is used to control the head’s movement speed. For general component like 0603, just keep default value
100. For special component like large IC, please adjust this value to slow down the movement speed.
Down speed: it is used to control the nozzle head’s Z-axis downward speed (Special notice: for lead pitch
distance<0.5mm, please set this to a lower speed).
Vision: against component to choose applicable vision method. Such as:
For resistor/ capacitor--- please select Flying calibration.
For component which does not require high precision --- you can also select No action.
For IC --- you can select IC correction or big IC correction according to different IC sizes. The two methods difference
is: IC correction is one shot recognition; big IC correction is separately taking photos for IC’s four corners. So, make sure
the complete image of the component can be taken if you choose IC correction, otherwise you can only select big IC
correction method.IC pre-rotation correction is to rotate the component to the placement angle at first and then perform the
placement.
Accuracy: including high speed and high accuracy. Generally normal resistor/ capacitor is default as high speed mode,
do not need to modify it; For IC, please select high accuracy mode.
Brightness: it refers to the brightness of component recognition (after component being picked up) in assembly
procedure.
Feeder type: two types for selection---Pneumatic and Electric .
Nozzle: you can select single nozzle or several nozzles in different cases, once selected, they’ll be automatically
assigned to each feeder. Notice: for edge position feeders, you can just use limited nozzle head to pick up components.
If you’re not sure, just click “Feeder Test” button under the nozzle selection part. It will pop out below, you can test