28
Zhejiang Neoden Technology Co., Ltd
ctual column and start Y will be its actual location of row.
(
2
)
Feeder basic info: fig(4.2.1)
Skip: once selected, all components in this feeder will be skipped
Feeder exchange: this function can be used if any reel tape was installed at wrong or inappropriate position. Select the
feeder/ IC tray feeder you need to exchange, then the related feeder info will be synchronized to the swapped feeder/
IC tray feeder.
Pick XY: Align the first component position in the feeder as fig, which is Mark camera align the component
central position, then click ”save and back”, the well-saved position’s X/Y coordinates will be automatically show up
as fig. (P.S.: pick position can be set one by one or be set by the scale setting, scale setting is more convenient).
Fig
(
4.2.1
)
Fig
(
4.2.2
)
Initial angle: default is 0°, in some special cases, you can change the mounting angle of the entire components by
modifying the angle here. Here specially pay attention to some components with direction requirement, such as LED
red/green, diode, IC chip etc.
Footprint/ Value: component footprint/ value. Footprint refers to the footprint name, such as 0603, 0805, 1206 etc.,
Value refers to component data, such as 10K, 75Ω etc.
Pick height:
Measuring method of pick height: you can bulk edit the pick position to measure the pick height. According to different
components, you can input appropriate pick height at first and click the nozzle to go down(if the feeder is cloesed, when
clicking nozzle to go down, the feeder will turn on automatically and then the nozzle goes down)to manually observe
whether the height is reasonable and make fine adjustment.