8
Zhejiang Neoden Technology Co., Ltd
1.4 Important Notice
Figure 6-The air supply of the equipment shall not be less than0.55MP
Figure 7- Feeder Pressure 0.5MP
Remark: At 0.55MPA pressure input, the air consumption of the machine is 12L/min. It is recommended to use a
compressed airtank of no less than 70L.
Warning of failure risk of camera identification
,
please referring to Figure 3 and
Figure 5
:
The following parts are forbidden to touch and impact
Front IC Camera
Back IC camera
Left mark camera
Right mark camera
Warning of accuracy failure risk, refer to Figure 3: The following components are
prohibited from touching and impacting.
Return to zero column
For the risk of accuracy failure, refer to Figure4: When manually moving XY, it must
be carried out on the X-axis beam moving point;
Warning of electric shock, be sure to follow the requirements below
:
Connect the input power supply that meets the requirements of the equipment, the
electrical interface of the machine to the ground must be effectively grounded
;
Any time you enter the case and stick to the head for maintenance, you need to shut
down
Warning of equipment life reduction
,
be sure to follow the requirements below
:
When installing the equipment, the equipment must be leveled
;
Correct shutdown: shut down the operating software and the system before turning off
the main power switch
;