17
Zhejiang Neoden Technology Co., Ltd
center of this component, click save and back, it will return to the “PCB information” automatically.
The data of “left top”on original board: on the alignment interface,find the left top panel,then find the component
same as the component that aligned on the “right top”,align the center of this component, click save and cancel, it will
return to the “PCB information” automatically.
The data of “left bottom”on original board:on the alignment interface,find the left bottom panel,then find the
component same as the component that aligned on the “right top”, align the center of this component. After saving the
data, it will return to the “PCB information” automatically.
The data of “left bottom”on mirror board:on the alignment interface,find the left bottom panel,then find the component
same as the component that aligned on the “right top”, align the center of this component. After saving the data, it will
return to the “PCB information” automatically.
After setup, click “create panelized list”, the panelized list will be generated accordingly in the blank. You can also
double-confirm each position by clicking “Align”. Note: The angel difference between original and mirror board is 180
degree, original board is 0 degree, mirror is 180 degree.
Skip: For the block component corresponding to the number entered in the panel number (edit box), if no
placement operation will be performed, then select “Yes” in the drop-down list.
Placement: For the block component corresponding to the number entered in the panel number (edit box), if
perform placement operation, then select ‘No’ in the drop-down list.
Recognition: Used for bad board detection. The current bad board detection function is still under development
and cannot be used yet.
4. Coordinate information
4.1 PCB Mark setting
PCB Mark setting interface see below fig.
:
1.PCB Mark Point
(
1
)
Panelized mark point
It is mainly used for multiple identical PCB boards consistent of the whole board, when place every panel board, the
machine will rescan small panel board’s mark point.
(
2
)
Single mark point