35
Zhejiang Neoden Technology Co., Ltd
the adjustment is complete, just save it.
(
10
)
Head Home back: click to move the head back to original left top position.
(
11
)
Nozzle Replace: click to replace nozzles, the head will move to its position for easier replacement.
(
12
)
Head Nozzle: click to test rotation, suction, blow and moving down functions of nozzle NO.1-NO.6.
(
13
)
Width Initialize: initialize the width of rails back to zero.
(
14
)
Width Set: after the initialization of rails width, enter the expected width, click Width Set, the rails be widened
accordingly.
(
15
)
Introduction of Lock interface, as below fig.
Save and back
:
After align the center of components,click
“
save and back
”
to save the date.
Close and Back:
Refer to exit the current interface.
Align method
:
Include left mark camera,nozzle 1-6,right mark camera,choose the alignment method according to the
actual situation,right side will show the real image by mark camera alignment.
Nozzle Down Test
:
When mark cameras are selected as the alignment mode, this function is gray and inoperable.
When selecting nozzle 1-6, this interface turns black and can be operated. The user must first lock the position, enter a
reasonable height value, and then click the nozzle down test button to measure whether the reclaiming height is reasonable.
(Note: when locking the interface to test the reclaiming height of Feida, feeder will not open automatically. You can select
the material above the edge of thecomponent to measure.)
Point 1, Point 2, Mid-point
:
This operation is used to select the center position of some components.
For example, select " left mark camera" as alignment mode. First select the center of the first pin of the lower left foot