-207-
Library error code (13/16)
Code(
H
)
Description
Panel
Indicator
Action
00C0
Picker cannot move because magazine was
removed.
(FRU)
Maintenance chassis
CHK
00C0
1. To power cycle the library.
2. Check the medium.
3. Check the magazine.
00C1
When I/O lock release (IOULK) operates, I/O
lock sensor OFF cannot be detected.
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00C1
1. To power cycle the library.
2. Check the magazine.
00C2
Reserved
-
00C3
Reserved
-
00C4
Reserved
-
00C5
Picker move error #7
(
Defect in moving to
RVS position(P1) during the motion other
than GET/PUT(Detected picker origin or
FWD).)
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00C5
1. To power cycle the library.
2. Check the medium.
3. Check the magazine.
00C6
Picker move error #8
(
Defect in moving to
FWD position (P2) during the motion other
than GET/PUT(Not Detected picker origin
or FWD).)
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00C6
1. To power cycle the library.
2. Check the medium.
3. Check the magazine.
00C7
Picker move error #9
(
Defect in moving to
medium
extrusion/medium
position
(P3/P4/P5/P6) during the motion other than
GET/PUT(Not Detected picker origin or
FWD).)
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00C7
1. To power cycle the library.
2. Check the medium.
3. Check the magazine.
00C8
Reserved
-
00C9
Picker calibration error #1 (Cannot detect
CTRG sensor ON during picker calibration.)
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00C9
Unless calibration operated, this
error does not occur.
00CA
Picker calibration error #2
(The encoder count became more than the P6
value during picker calibration.)
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00CA
1. To power cycle the library.
2. Check the medium.
3. Check the magazine.
00CB
Picker calibration error #3
(The lock position was not able to be detected
during picker calibration.)
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00CB
1. To power cycle the library.
2. Check the medium.
3. Check the magazine.
00CC
GET motion error during Picker calibration
(Not detected CTRG sensor ON in GET
motion during Picker calibration.)
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00CC
1. To power cycle the library.
2. Check the medium.
3. Check the magazine.
00CD
Reserved
-
00CE
Not detected lock position during LIMIT
CHECK motion
(FRU)
Maintenance chassis,
CHK
00CE
1. To power cycle the library.
2. Check the medium.
3. Check the magazine.