-209-
Library error code (14/16)
Code(
H
)
Description
Panel
Indicator
Action
00D0
Detected check sum error during firmware
update.
(FRU)
F/W
CHK
00D0
To power cycle the library.
00D1
Detected firmware ID error during firmware
update.
(FRU)
F/W
CHK
00D1
To power cycle the library.
00D2
Detected boot information error during
firmware update.
(FRU)
F/W
CHK
00D2
To power cycle the library.
00D3
Stopped processing because BCR does not
become Maintenance mode when BCR
firmware updating.
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00D3
To power cycle the library.
00D4
Detected error during BCR F/Wchecking
(FRU)
Maintenance chassis, F/W
CHK
00D4
To power cycle the library.
00D5
Reserved
-
00D6
The lock could not be released at the time of
magazine ejection.
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00D6
To power cycle the library.
00D7
The lock could not be released at the time of
I/O station opening.
(FRU)
Maintenance chassis,
CONTROLLER BOARD
CHK
00D7
To power cycle the library.
00D8
Power supply #1 FAN error was detected
(FRU)
Power supply #1
CHK
00D8
00D9
Power supply #2 FAN error was detected
(FRU)
Power supply #2
CHK
00D9
00DA
Reserved
-
00DB
Reserved
-
00DC
Power supply #1 error was detected
(FRU)
Power supply #1
CHK
00DC
00DD
Power supply #2 error was detected
(FRU)
Power supply #2
CHK
00DD
00DE
Reserved
-
00DF
Reserved
-