4-18
Upgrading Your System
Place the heat sink clip on the center tab of the retention module and
rotate the clip towards the heat sink to engage the center tab. Repeat
this step with the second clip. See Figure 4-17.
While ensuring the heat sink is level and secure with one hand, snap
one end of the clip down over the corresponding tab on the retention
module. Then snap the opposite corner clip. Snap the remaining end
of the clips down over the corresponding tabs. Be sure the clip is
adequately engaged with the tab. Ensure the heat sink is absolutely
level. See Figure 4-17.
Figure 4-17. Installing the Heat Sink and Clips
13.
Install the plastic processor air duct removed in Step 5 of this procedure. See
Figure 4-12.
14.
Reinstall the top cover on the system chassis. See
Top Cover Installation
found
earlier in this chapter.
15.
Plug in the system power cord(s).
16.
Power on the server, start the BIOS SETUP utility, and set "Processor
Retest" of "Processor Settings" on the Main menu to "Enable".
17.
Reboot the system. Verify that POST displays no error messages. If POST
displays an error message, take a note on the message and see the POST
error messages listed in Chapter 5.
18.
Set "Reset Configuration Data” under the Advanced menu to "Enable". This
setting is required to change the hardware configuration data. Reboot the
system.
19.
Reinstall the server into the rack.
Summary of Contents for Express5800/120Rf-2
Page 1: ... U s e r s G u i d e EXPRESS5800 120Rf 2 ...
Page 2: ......
Page 4: ......
Page 10: ...viii Contents ...
Page 61: ...Setting Up the System 2 29 Figure 2 34 Making Connections ...
Page 80: ......
Page 186: ...5 22 Problem Solving ...
Page 187: ...A Specifications System Specifications ...
Page 197: ...C Interrupt Requests ...
Page 199: ...Interrupt Requests C 3 ...
Page 209: ...10 Glossary ...
Page 214: ...xx ...
Page 215: ... 456 01669 000 ...