CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
Preliminary User’s Manual U16315EJ1V0UD
136
Figure 6-4. Format of 16-Bit Timer Output Control Register 00 (TOC00)
Address: FFBDH After reset: 00H R/W
Symbol
7
6
5
4
3
2
1
0
TOC00
0
OSPT00
OSPE00
TOC004
LVS00
LVR00
TOC001
TOE00
OSPT00
One-shot pulse output trigger control via software
0
No one-shot pulse trigger
1
One-shot pulse trigger
OSPE00
One-shot pulse output operation control
0
Successive pulse output mode
1
One-shot pulse output mode
Note
TOC004
Timer output F/F control using match of CR010 and TM00
0
Disables inversion operation
1
Enables inversion operation
LVS00
LVR00
16-bit timer/event counter 00 timer output F/F status setting
0
0
No change
0
1
Timer output F/F reset (0)
1
0
Timer output F/F set (1)
1
1
Setting prohibited
TOC001
Timer output F/F control using match of CR000 and TM00
0
Disables inversion operation
1
Enables inversion operation
TOE00
16-bit timer/event counter 00 output control
0
Disables output (output fixed to level 0)
1
Enables output
Note
The one-shot pulse output mode operates correctly only in the free-running mode and the mode in which
clear & start occurs at the TI000 valid edge. In the mode in which clear & start occurs on a match between
the TM00 register and CR000 register, one-shot pulse output is not possible because an overflow does not
occur.
Cautions 1. Timer operation must be stopped before setting other than TOC004.
2. If LVS00 and LVR00 are read after data is set, 0 is read.
3. OSPT00 is automatically cleared after data is set, so 0 is read.
4. Do not set OSPT00 to 1 other than in one-shot pulse output mode.
5. A write interval of two cycles or more of the operating clock is required to write to OSPT00
successively.