![NANOTEC PD4-C5918M4204-E-01 Manual Download Page 57](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520057.webp)
Manual PD4-C (USB)
9 Operating modes
Version: 1.4.1 / 22.07.2016 / FIR-v1626
57
Index pulse
Negative
limit switch
1
Method 2 references a positive limit switch and index pulse:
2
Index pulse
Positive
limit switch
Methods 3 to 6
These methods reference the switch flank of the reference switch and index pulse.
In the methods 3 and 4, the left switch flank of the reference switch is used as a reference:
Index pulse
3
3
4
4
Reference
switch
In the methods 5 and 6, the right switch flank of the reference switch is used as a reference:
Index pulse
5
5
6
6
Reference
switch
Methods 7 to 14
These methods reference the home switch and index pulse (with limit switches).