Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
201
Change History
Firmware Version FIR-v1626: Entry "Saveable" modified from "No" to
"yes, category: application".
Description
The nominal current in object 203B
:01
h
is equal to a nominal torque. This object is expressed as per
thousand of this nominal torque, e.g. the value "500" means "50%" of the nominal torque, "1100" is
equal to 110%. This value cannot exceed the peak torque (generated by peak current in 2031
).
6072h Max Torque
Function
The object describes the maximum torque.
Object description
Index
6072
h
Object Name
Max Torque
Object Code
VARIABLE
Data type
UNSIGNED16
Saveable
yes, category: application
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
0000
h
Firmware Version
FIR-v1426
Change History
Description
The nominal current in object 203B
:01
h
is equal to a nominal torque. This object is expressed as per
thousand of this nominal torque, e.g. the value "500" means "50%" of the nominal torque, "1100" is
equal to 110%. This value cannot exceed the peak torque (generated by peak current in 2031
).
6074h Torque Demand
Function
Current output value of the ramp generator (torque) for the internal control.
Object description
Index
6074
h
Object Name
Torque Demand
Object Code
VARIABLE
Data type
INTEGER16
Saveable
No
Access
Read only
PDO Mapping
TX - PDO
Admissible Values
Specified Value
0000
h