Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
163
Data type
UNSIGNED32
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
00000000
h
Sub-index
07
h
Name
Differential Select
Data type
UNSIGNED32
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
00000000
h
Sub-index
08
h
Name
Routing Enable
Data type
UNSIGNED32
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
00000000
h
Description
The subentries have the following function:
•
01
h
: This sub-index switches on the special functions of the respective input if the bit has the value
"1".
•
02
h
: This sub-index inverts the logic of an input if the respective input has the value "1".
•
03
h
: This sub-index forces an input value if the bit has the value "1". An input with a forced value is
always set to the value entered in subentry 4
h
regardless of the applied voltage level.
•
04
h
: This sub-index specifies the input value to be forced.
•
05
h
: This sub-index always contains the read, unmodified input value.
•
06
h
: This sub-index switches the switching thresholds between 5 V (value "0" in the sub-index) and
24 V (value "1" in the sub-index) for all inputs at once.
•
07
h
: This sub-index switches the inputs from a single ended (value "0" in the sub-index) to
differential (value "1" in the sub-index) for all inputs at once.
•
08
h
: This sub-index enables "Input Routing" when the value "1" is written to it.
3241h Digital Input Capture
Function
With this object the encoder position can autocratically get captured when a change of level at digital
input 2 occurs.
Object description
Index
3241
h
Object Name
Digital Input Capture
Object Code
ARRAY
Data type
UNSIGNED32