![NANOTEC PD4-C5918M4204-E-01 Manual Download Page 112](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520112.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
112
2052h Encoder Resolution
Function
Contains the resolution of the encoder that is used for electrical commutation.
Object description
Index
2052
h
Object Name
Encoder Resolution
Object Code
VARIABLE
Data type
INTEGER32
Saveable
yes, category: tuning
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
•
: 00000000
h
•
PD4-C5918M4204-E-01: 00001000
h
•
PD4-C6018L4204-E-01: 00001000
h
•
PD4-CB59M024035-E-01: 00001000
h
•
PD4-C5918L4204-E-01: 00001000
h
•
PD4-C5918M4204-KSAR2: 00001000
h
Firmware Version
FIR-v1426
Change History
Firmware Version FIR-v1540: Entry "Saveable" modified from "No" to
"yes, category: tuning".
Description
A negative value means that the encoder is operated in the opposite direction to the motor. This can be
corrected by changing the poles of the motor winding.
2056h Limit Switch Tolerance Band
Function
Specifies how far positive or negative limit switches may be overrun before the motor controller issues
an error.
This tolerance range is required, for example, to be able to complete reference runs - in which limit
switches can be activated - error-free.
Object description
Index
2056
h
Object Name
Limit Switch Tolerance Band
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: application
Access
Read/write
PDO Mapping
TX - PDO
Admissible Values