![NANOTEC PD4-C5918M4204-E-01 Manual Download Page 214](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520214.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
214
Change History
Description
The ramp is only used when starting off. When the switch is reached, the unit is automatically switched
to the lower speed and is stopped as soon as it reaches the limit position.
60A4h Profile Jerk
Function
In case of a jerk-limited ramp, the magnitude of the jerk can be entered in this object. An entry with the
value "0" means that the jerk is not limited.
Object description
Index
60A4
h
Object Name
Profile Jerk
Object Code
ARRAY
Data type
UNSIGNED32
Saveable
yes, category: application
Firmware Version
FIR-v1426
Change History
Firmware Version FIR-v1614: Entry "Name" modified from "End
Acceleration Jerk" to "Begin Deceleration Jerk".
Firmware Version FIR-v1614: Entry "Name" modified from "Begin
Deceleration Jerk" to "End Acceleration Jerk".
Value description
Sub-index
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
Read only
PDO Mapping
No
Admissible Values
Specified Value
04
h
Sub-index
01
h
Name
Begin Acceleration Jerk
Data type
UNSIGNED32
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
000003E8
h
Sub-index
02
h
Name
Begin Deceleration Jerk
Data type
UNSIGNED32
Access
Read/write
PDO Mapping
No
Admissible Values