![NANOTEC PD4-C5918M4204-E-01 Manual Download Page 183](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520183.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
183
Description
This object controls the " DS402 Power State machine". The function of parts of the object are
depending on the currently selected mode.
OMS [3]
FR
EV
SO
EO
QS
OMS HALT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SO (Switched On)
Value = "1": Switches to the "Switched on" state
EV (Enable Voltage)
Value = "1": Switches to the "Enable voltage" state
QS (Quick Stop)
Value = "0": Switches the "Quick stop" state
EO (Enable Operation)
Value = "1": Switches to the "Enable operation" state
OMS (Operation Mode Specific)
Meaning depends on the selected operating mode
FR (Fault Reset)
Resets an error (if possible)
HALT
Value = "1": Triggers a stop, available in the following modes:
•
•
•
•
6041h Statusword
Function
This object queries whether the state commanded with object 6040
(control word) has been reached.
Object description
Index
6041
h
Object Name
Statusword
Object Code
VARIABLE
Data type
UNSIGNED16
Saveable
No
Access
Read only
PDO Mapping
TX - PDO
Admissible Values
Specified Value
0000
h
Firmware Version
FIR-v1426
Change History