2059h Encoder Configuration
Function
This object specifies the supply voltage of the encoder.
Object description
Index
2059
h
Object Name
Encoder Configuration
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: tuning
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00000000
h
Firmware Version
FIR-v1426
Change History
Firmware Version FIR-v1614: Entry "Saveable" modified from "yes,
category: application" to "yes, category: tuning".
Description
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TYPE
VOLT
Setting this bit to the value "0" the supply voltage of the encoder is set to 5V. Setting this bit to
the value "1" the supply voltage of the encoder is set to 24V.
TYPE
Defines the type of the encoder. This bit has to be set to the value "0" if a differential encoder is
used. For a single ended encoder, the bit has to be set to the value "1".
205Ah Encoder Boot Value
Function
This object has only a functional purpose, if an absolute encoder is used: From this object, the encoder
position (in user units) can be read, which was read from the absolute encoder initially at power up of
the controller. This object is always 0 if no absolute encoder is used.
Object description
Index
205A
h
Object Name
Encoder Boot Value
Object Code
VARIABLE
Data type
UNSIGNED32