Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
109
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00000000
h
Description
The subentries are divided into two groups: sub-index 01
h
and 02
h
holding parameter for controlling,
sub-index 03
h
to 06
h
are status values. The functions are as follows:
•
01
h
: Specifies the nominal current as root mean square (RMS) in mA, must be smaller than the
, otherwise monitoring will not be activated.
•
02
h
: Specifies the maximum time period of the peak current in ms.
•
03
h
: Threshold, specifies the limit in mA, from which is determined whether switching is to the
maximum current or nominal current.
•
04
h
: CalcValue, specifies the calculated value that is compared to the threshold in order to set the
current.
•
05
h
: LimitedCurrent, shows the actual current value as root mean square (RMS) that was set by I
2
t.
•
06
h
: Actual status. If the subentry value is "0", I
2
t is deactivated; if the value is "1", I
2
t is activated
203Dh Torque Window
Function
Specifies a symmetrical range relative to the target torque within which the target is considered to be
reached.
If the value of the torque window is FFFFFFFF
h
, the torque window control is switched off, the bit
"target reached" in object 6041
h
(Statusword) will never get set..
Object description
Index
203D
h
Object Name
Torque Window
Object Code
VARIABLE
Data type
UNSIGNED16
Saveable
yes, category: application
Savable
No
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
0000
h
Firmware Version
FIR-v1540
Change History
Firmware Version FIR-v1614: Entry "Saveable" modified from "No" to
"yes, category: application".
203Eh Torque Window Time
Function
For this time period in milliseconds, the actual torque must be within the "Torque Window" (203D
) for
the target velocity to be considered as reached.