© Ernst Nagel GmbH 2S Trimmer Service Manual en.doc Rev.1.0. 20.07.2011
64
Contents
5. Troubleshooting
(continued)
5.3 Fault Code Solutions
(continued)
STR 033
Stacker Motor1 Short Circuit
Procedure
Disconnect the Stacker Motor connector J12. Run the diagnostics.
Fault code STR 032(Open Circuit) is displayed?
Y N
Disconnect connector J1. Check wires for Short Circuit across leads. (Orange5 & Violet 11)
Is there a short Circuit?
Y N
Disconnect plug 1P2 from PCB1 Check wires for Short Circuit across leads.
(Orange3 & Violet10)
Is there a Short Circuit?
Y N
Replace
PCB1
Replace
wire
harness
Replace
wire
harness
Replace Stacker Motor
STR 041
Jogger1 Not Home
Procedure
Check Jogger1 switch (S11).
Is the switch activated?
Y N
Check if Side Jogger isn’t damaged or loosened.
Side Jogger is ok?
Y N
Replace
Side
Jogger
Correct NVM values of Side Jogger
Check if S11 is activated using the service menu.
S11 is activated?
Y N
Replace
wire
harness
Retest procedure