© Ernst Nagel GmbH 2S Trimmer Service Manual en.doc Rev.1.0. 20.07.2011
60
Contents
5. Troubleshooting
(continued)
5.3 Fault Code Solutions
(continued)
STR 025
Motor8 Pulse Timeout
Procedure
STR 026
Motor8 Cycle Timeout
•
Go
to
STR 027 – Motor8 Open Circuit
Warning : Fault code STR025 can be caused by a NVM 4 Infeed Position that is to high.
Enter the Service mode and select Motor8 encoder A in sensors. Slowly rotate the motor by hand and check the value on the display.
Value toggles between “0” and “1”?
Y N
Disconnect the sensor plug to Motor8 (STR-Motor8). Measure between the two wires for the sensor (5V and Signal ground).
The voltage is approximately 5VDC?
Y N
Check
wires
for
damage.
Are the wires damaged?
Y N
Go to
STR 027 Motor 8 Short Circuit
Replace
wire
Harness
Replace
Sensor
Enter the Service mode and select Motor8 encoder B in sensors. Slowly rotate the motor by hand and check the value on the display.
Value toggles between “0” and “1”?
Y N
Disconnect the sensor plug to Motor8 (STR-Motor8). Measure between the two wires for the sensor (5V and Signal ground).
The voltage is approximately 5VDC?
Y N
Check
wires
for
damage.
Are the wires damaged?
Y N
Go to
STR 027 Motor 8 Short Circuit
Replace
wire
Harness
Replace
Sensor
Enter service mode and start Motor8.
The motor starts?
Y N
Go
to
STR 028 Motor 8 Open Circuit
Check for obstructions