© Ernst Nagel GmbH 2S Trimmer Service Manual en.doc Rev.1.0. 20.07.2011
118
Contents
6. Default / basic adjustments
(continued)
6.9 Adjusting Thickness detection
Fig.
6.65
Fig.
6.66
Fig.
6.67
Fig. 6.68
Fig.
6.69
Fig.
6.70
Adjusting
No. Action
Remarks
1
Make a booklet 25 sheets 80gms and a booklet 27 sheets 80gms.
2
Enter the Service Program mode, select Sensors and press 2
times Next and select Sensor ‘FC6 Thickness’ and press ‘Enter’.
(See Chap.
5.15
& Fig. 6.69)
3
Place the booklet 25 sheets halfway the Infeed of the STR.
(See Fig. 6.65 & 6.66)
4
Adjust screw ‘A’ of the Thickness detection from inside the STR:
By booklet 25 sheets 80gms the Value should be Low .
NOTE!:
Do not press to hard by adjusting screw A otherwise
the Thickness detection is pressed backwards!
(See Fig. 6.70)
(See Fig. 6.67 & 6.68)
5
Place the booklet 27 sheets halfway the Infeed of the STR.
(See Fig. 6.65 & 6.66)
6
Adjust screw ‘A’ of the Thickness detection from inside the STR:
By booklet 27 sheets 80gms the Value should be High.
NOTE!:
Do not press to hard by adjusting screw A otherwise
the Thickness detection is pressed backwards!
(See Fig. 6.70)
(See Fig. 6.67 & 6.68)
A
CW =
Trim
thicker
booklets
CCW =
Trim
thinner
booklets