© Ernst Nagel GmbH 2S Trimmer Service Manual en.doc Rev.1.0. 20.07.2011
58
Contents
5. Troubleshooting
(continued)
5.3 Fault Code Solutions
(continued)
STR 021
Motor7 Pulse Timeout
Procedure
STR 022
Motor7 Cycle Timeout
•
Go
to
STR 024 – Motor7 Open Circuit
Warning : Fault code STR021 can be caused by a NVM 2 Infeed Position that is to high.
Enter the Service mode and select Motor7 encoder A in sensors. Slowly rotate the motor by hand and check the value on the display.
Value toggles between “0” and “1”?
Y N
Disconnect the sensor plug to Motor7 (STR-Motor7). Measure between the two wires for the sensor (5V and Signal ground).
The voltage is approximately 5VDC?
Y N
Check
wires
for
damage.
Are the wires damaged?
Y N
Go to
STR 023 Motor 7 Short Circuit
Replace
wire
Harness
Replace
Sensor
Enter the Service mode and select Motor7 encoder B in sensors. Slowly rotate the motor by hand and check the value on the display.
Value toggles between “0” and “1”?
Y N
Disconnect the sensor plug to Motor7 (STR-Motor7). Measure between the two wires for the sensor (5V and Signal ground).
The voltage is approximately 5VDC?
Y N
Check
wires
for
damage.
Are the wires damaged?
Y N
Go to
STR 023 Motor 7 Short Circuit
Replace
wire
Harness
Replace
Sensor
Enter service mode and start Motor7.
The motor starts?
Y N
Go
to
STR 024 Motor 7 Open Circuit
Check for obstructions