Rev. 10-7-16
Part #C-00140
GT20 Control Wiring and Programming Manual
Programming
7-33
Element
lu
Description
UL Version Software changed due to UL specifications
HW Version Version of Logic PCB
Cycles
Total number of openings (this value is memorized).
R0 R1 FP RP Displays what the Door Panel is doing.
R0 Relay print with address 0
- Identified and ready for operation
R1 N/A
+ Neither identified nor registered
FP N/A
a Defective or Error
RP N/A
x Removed
Table 7-10
Error Active: For detailed Error Tables please refer to Chapter 18.
Element
Description
ERROR ACTIVE
Error Active list is updated with the latest additions appearing at the end.
A0 indicates the most recent Active Error.
Table 7-11
History Error
Element
Description
HISTORY ERROR
List of Active Errors that were detected and corrected or not corrected.
H0 indicates the most recent Active Error
Table 7-12
REINIT Menu: Reverts Settings back to Factory Default
Element
Description
FACTORY RESET
All settings that were programmed into the GT Control will be reset to Factory Defaults.
PARAM RESET
Resets/Sets all motional Parameters back to the default values (inclusive opening angle,
rod assemblies, Invers and dAxix
CONFIG RESET
Reset sets all the configuration settings back to the default values.
DOUBLE RESET
Reset sets all the closing sequence and interlock settings back to the default values.
Table 7-13
Block/Unblock Menu: Lock Keys
Menu
Description
Block?
To lock the Joystick
Press OK for 2 seconds
The Display shows temporarily
BLOCK!
UBLOC?
To unlock the Joystick
Press OK for 2 seconds
The Display shows temporarily
UBLOC!
BlockD
When the Joystick is blocked, the "Home display" shows
BLOCKD
, if the Joystick is operated!
Table 7-14
Update SoftWare: For detailed Software Update instructions please refer to Chapter 19.
Element
Description
Update SW
Updates the latest version of software.
Table 7-15
Teach Menu
Element
Description
TEACH OK?
Programs the Setup Procedure within the GT20 Control.