Namron Panelovn Zigbee Instruction Manual 

Function introduction

Important: 

Read All Instructions Prior to Installation

1. Product Data

Segment digital display

OK button

Radio Frequency

Operation Mode

Measurement range

Set Temperature Range

Hysterersis

Ambient Temperature

• 

The Zigbee heating panel is a wireless heating device, which complies to Zigbee 3.0 wireless protocol 

standards. The thermostat has 3 operation modes which can be controlled manually and locally or through 
remote controlled through Zigbee gateway controller.

• 

All setup is performed via supported IEEE 802.15.4-based control platforms and other Zigbee3.0 compatible 

control systems. 

• 

Operation Modes: OFF,  MANUAL,AUTO

• 

Measurement range: 0°C to +60°C

• 

WARNING: Electrical power must be switched off during installation

2.4GHz

OFF,  MANUAL,AUTO 

0°C to +60°C

5°C to 35°C

0.5°C to 2°C

0°C to 40°C (during operation)

Revised 04.01.2022

• DO NOT install with power applied to device.
• DO NOT expose the device to moisture.

Safety & Warnings

button

button

Summary of Contents for Panelovn Zigbee

Page 1: ...as 3 operation modes which can be controlled manually and locally or through remote controlled through Zigbee gateway controller All setup is performed via supported IEEE 802 15 4 based control platfo...

Page 2: ...for 3 minutes the network icon flashes slowly once added to a network successfully the network icon will turn on for 3 seconds OFF status or stay solid on non OFF status or reset power of the device...

Page 3: ...x0201 When Window Open Detect mode is activated the icon will stay solid on Once the device is powered on and working stable if the temperature decreases to 5 C within 10 minutes the window open mark...

Page 4: ...e v o s i e r u t a r e p m e t B C P e h t f I A s been forced a temperature between 85 C 90 C to work for 30 seconds the device will work normally for another 30 seconds then it will be forced to st...

Page 5: ...e consists of a pre set on off state value You may either store the current values as a scene or provide scene settings when adding a scene or delete scenes 0x0201 Thermostat Groups Allows adding this...

Page 6: ...lid attribute is true this attribute together with the CurrentGroup attribute indicates the currently active scene 0x0002 int16u read only CurrentGroup If the SceneValid attribute is true this attribu...

Page 7: ...ove Group Removes this endpoint from the specified group Also removes all scenes that refer to this group 0x04 Remove All Groups Removes this endpoint from all groups Also removes all scenes that refe...

Page 8: ...last status before power off Default 0x1004 ENUM8 reportable 0x1224 DisplayAutoOffActivation 0 deactivated default 1 activated Proprietary Attributes Attribute Type Description 0x1000 ENUM8 reportable...

Page 9: ...tmap8 read only MeteringDeviceType The metering data type this is always Electric Metering 0x00 0x0302 Int24U read only Divisor 3 2 6 Electrical Measurement 0x0b04 Server Attributes supported Attribut...

Page 10: ...isor 0x0a 10 used together with above attribute real displayed power ActivePower ACPowerMultiplier ACPowerDivisor ACPowerMultiplier 0x01 0x0800 int16U ACAlarmsMask Specifies which configurable alarms...

Page 11: ...support 3 2 10 Thermostat User Interface Configuration 0x0204 Server Attributes supported Attribute Type Description Attributes supported 3 2 8 Time 0x000A server The Time cluster is a general cluste...

Reviews: