UnixWare
Manual No. 771929
5-19
5
U
N
I
X
W
A
R
E
drives, ready drives, standby drives, and drives not present. The top row
corresponds to channel 0, and the left most column is for SCSI ID 0.
To perform a manual rebuild, identify the drive channel and SCSI ID of the
dead drive. Use the arrow keys to highlight the drive to be rebuilt, then press
the Enter key to start the rebuild process. The rebuild is complete when all
the dependent System Drives are rebuilt.
At the end of a successful rebuild operation, all System Drives dependent
upon this SCSI drive are brought back to consistency, and the state of the
SCSI drive is set to ON-LINE. If bad sectors are found on any of the System
Drives, those sectors cannot be rebuilt. The rebuild utility will, nevertheless,
bring the new disk ON-LINE anyway.
Mylex Disk Array Controller Toolkit. Select Toolkit, for the same
message and menu as if using dac960tk in the command mode (described
earlier in this chapter).
Quit. Select this item to exit from the shell and return to the normal
UnixWare prompt.
Summary of Contents for Disk Array controller Software Kit 2.01
Page 2: ......
Page 6: ......
Page 12: ...xii Disk Array Controller Software Kit User s Manual...
Page 20: ...Requirements 1 8 Disk Array Controller Software Kit User s Manual...
Page 124: ...Shell Utility for UnixWare 5 20 Disk Array Controller Software Kit User s Manual...
Page 154: ...Installing TCP IP Windows NT B 4 Disk Array Controller Software Kit User s Manual...
Page 171: ......