Shell Utility for SCO UNIX
4-20
Disk Array Controller Software Kit User’s Manual
Select Rebuild from the menu bar, and the center of the screen shows the
status of all drives on all channels. The symbols ONL, DED, WOL, RDY,
SBY, and ---- are used to indicate on-line drives, dead drives, write only
drives, ready drives, standby drives, and drives not present. The top row
corresponds to channel 0, and the left most column is for SCSI ID 0.
To perform a manual rebuild, identify the drive channel and SCSI ID of the
dead drive. Use the arrow keys to highlight the drive to be rebuilt, then press
the Enter key to start the rebuild process. The rebuild is complete when all
the dependent System Drives are rebuilt.
At the end of a successful rebuild operation, all System Drives dependent
upon this SCSI drive are brought back to consistency, and the state of the
SCSI drive is set to ON-LINE.
If bad sectors are found on any of the System Drives, those sectors cannot be
rebuilt. The rebuild utility will, nevertheless, bring the new disk ON-LINE
anyway.
Mylex Disk Array Controller Toolkit. Select Toolkit, and you will see the
same message and menu as you did using dac960tk in the command mode.
Refer to the section Toolkit described earlier in this chapter for details of its
commands.
Quit. Select this item to exit from the shell and return to the normal SCO
UNIX prompt.
Summary of Contents for Disk Array controller Software Kit 2.01
Page 2: ......
Page 6: ......
Page 12: ...xii Disk Array Controller Software Kit User s Manual...
Page 20: ...Requirements 1 8 Disk Array Controller Software Kit User s Manual...
Page 124: ...Shell Utility for UnixWare 5 20 Disk Array Controller Software Kit User s Manual...
Page 154: ...Installing TCP IP Windows NT B 4 Disk Array Controller Software Kit User s Manual...
Page 171: ......