Mylex Disk Array Controller Driver for NetWare 5.0
2-10
Disk Array Controller Software Kit User’s Manual
Installing the Mylex Disk Array Controller into an Existing
NetWare 5.0 System
If NetWare 5.0 is already installed and you wish to add a Mylex Disk Array
Controller later, the controller will be a secondary (non-bootable) controller.
After installing the controller hardware and configuring a disk array, follow
the procedure below to add the necessary controller drivers.
1. With NetWare Server 5.0 loaded and running, load the NetWare
program by typing the following at the console prompt:
: load nwconfig
and press <Enter>.
2. Choose “Driver Options” in the Installation Options menu.
3. Copy NWASPI.CDM (for GAM support) from the Novell distribution
CD-ROM.
• Be sure you are in this directory; \DRIVERS\STORAGE\ and copy
NWASPI.CDM to this directory; C:\NWSERVER.
• Add NWASPI.CDM to the STARTUP.NCF file.
• Add LOAD NWASPI.CDM right after the line, LOAD
SCSICD.CDM
4. Press the arrow keys to return to installation.
5. Choose “Configure disk and storage device drivers” in the Driver
Options menu.
6. Choose “Select an additional driver” in the Additional Driver Actions
menu.
NetWare scans for controllers that do not have drivers already loaded.
7. At the “Select a driver” box, press <Ins> to choose to install an unlisted
driver.
8. Insert the NT/NW Drivers Software Kit distribution diskette into the
diskette drive.
9. Press <F3> to specify the path of the NetWare driver you’re about to
install.
Summary of Contents for Disk Array controller Software Kit 2.01
Page 2: ......
Page 6: ......
Page 12: ...xii Disk Array Controller Software Kit User s Manual...
Page 20: ...Requirements 1 8 Disk Array Controller Software Kit User s Manual...
Page 124: ...Shell Utility for UnixWare 5 20 Disk Array Controller Software Kit User s Manual...
Page 154: ...Installing TCP IP Windows NT B 4 Disk Array Controller Software Kit User s Manual...
Page 171: ......