Appendix E
46
Recommendations
Recommendations
Unit
Type
ISO 4406:1999 Code
PUMP
Piston (slow speed, in-line)
22/20/16
Piston (high speed, variable)
17/15/13
Gear
19/17/15
Vane
18/16/14
MOTOR
Axial piston
18/16/13
Radial piston
19/17/13
Gear
20/18/15
Vane
19/17/14
VALVE
Directional (solenoid)
20/18/15
Pressure control (modulating) 19/17/14
Flow control
19/17/14
Check valve
20/18/15
Cartridge valve
20/18/15
Proportional
18/16/13
Servo-valve
16/14/11
ACTUATOR
20/18/15
Table I
Typical Manufacturers Recommendations for Com-
ponent Cleanliness (ISO 4406:1999)
Most component manufacturers know the proportionate effect that increased dirt
level has on the performance of their components and issue maximum permissi-
ble contamination levels. They state that operating components on fluids which
are cleaner than those stated will increase life. However, the diversity of hydraulic
systems in terms of pressure, duty cycles, environments, lubrication required, con-
taminant types, etc, makes it almost impossible to predict the components service
life over and above that which can be reasonably expected. Furthermore, without
the benefits of significant research material and the existence of standard contami-
nant sensitivity tests, manufacturers who publish recommendations that are cleaner
than competitors may be viewed as having a more sensitive product.
Hence there may be a possible source of conflicting information when comparing
cleanliness levels recommended from different sources.
It should be noted that the recommendations made in this table should be viewed as starting levels and