EDS-405A/408A Series User’s Manual
Featured Functions
3-12
Set DIP switch as Turbo Ring / Set DIP switch as Turbo Ring V2
Setting
Description
Factory Default
Set DIP switch as
Turbo Ring
Select this option to enable the Turbo Ring
DIP switches to configure the EDS for a
“Turbo Ring” ring.
This is the default if you do
NOT reset the switch to
factory default settings
(provided you upgraded the
firmware for Turbo Ring
V2).
Set DIP switch as
Turbo Ring V2
Select this option to enable the Turbo Ring
DIP switches to configure the EDS for a
“Turbo Ring V2” ring.
This is the default if you
DO reset the switch to
factory default settings
(provided you upgraded the
firmware for Turbo Ring
V2).
NOTE
If you upgrade the firmware of your EDS from Turbo Ring to Turbo Ring V2, but do not reset the
switch to factory defaults, the DIP switches will be set to configure the EDS for a “Turbo Ring”
ring. If you reset the switch to factory defaults, the DIP switches will be set to configure the EDS
for a “Turbo Ring V2” ring.
How to Configure the Turbo Ring DIP Switches
The Turbo Ring DIP Switches are set to the OFF position at the factory.
NOTE
The four DIP Switches are used to configure both the “Turbo Ring”
and “Turbo Ring V2” protocols, depending on which protocol is
active. To select which protocol the EDS will use, start the user
interface software, and then use the left menu to navigate to the
Communication Redundancy
page. To use one of the Turbo Ring
protocols for the EDS, select either “Turbo Ring” or “Turbo Ring V2”
in the
Redundancy Protocol
drop-down box. See the
Configuring
“Turbo Ring” and “Turbo Ring V2”
section in this chapter for
details.
12
------
MASTER
COUPLER
TURBO
RING
34
The following tables show how to use the DIP switches to configure the EDS for “Turbo Ring” or
“Turbo Ring V2.”
NOTE
DIP switch 4 must be set to the ON position to enable DIP switches 1, 2, and 3. If DIP switch 4 is
set to the “OFF” position, then DIP switches 1, 2, and 3 will all be disabled.