Test the functioning of the system each time the engine is inspected. In particular, follow the
following steps:
–
Check the functioning of the analog outputs.
–
Check the functioning of the digital outputs.
–
Ensure that the sensors and wires are firmly connected.
11.1
Repair and Maintenance Work on the ATEX Enclosure
–
Repair and maintenance work on the ATEX enclosure may only be carried out by authorized
and appropriately trained personnel.
–
Maintenance and repair must be carried out in accordance with EN 60079-17.
–
During maintenance, in particular the parts on which the protection class depends must be
checked. This includes in particular the seals and the sealing system as well as lead
bushings.
–
The maintenance intervals must be selected depending on the operating conditions and the
operating time.
–
When operating the ATEX enclosure, the applicable national regulations of the country of
use must be observed.
11.2
Spare Parts and Accessories
For spare parts and accessories, please refer to our current Product Guide, which is available for
you to download on the internet at
www.motortech.de
.