2 Safety Instructions
12
Rev. 02/2019
Operational safety
Please note that the
detonation
sensors must be mounted according to the
firing order of the cylinders. Refer to the pertinent section
Wiring of the
Detonation Sensors
on page 57.
Detonation detection
The DetCon detonation controller detects knocking as far as possible, but
not bindingly.
DetCon only usable in single ignition mode
V-engines can only use the DetCon detonation controller with single
ignition and not in double ignition mode.
The DetCon uses two time windows per cylinder to detect engine knocking.
These time windows are opened in single ignition mode based on the
ignition pulse. In double ignition mode it is not possible to correctly assign
the time windows to all cylinders.
2.4
Proper Disposal
After the expiration of its service life, MOTORTECH equipment can be disposed of with other
commercial waste, or it may be returned to MOTORTECH. We will ensure its environmentally
friendly disposal.