5 Installation Instructions
Rev. 02/2019
47
Type examination certificate
All lead bushings and cable bushings must have a separate EC type
examination certificate.
Dummy plugs used require a separate EC type examination certificate.
Operational safety
All lead bushings must be mounted with a metal locknut.
When using lead bushings with strain relief and bending protection, the
number of possible standard lead glands is reduced.
Mixed fitting of lead bushings is possible. Areas for intrinsically safe
circuits must be marked separately.
Unused openings for lead bushings must be closed with blind plugs made
of cold impact resistant plastic or metal.
The lead bushings must be mounted in such a way that independent
loosening is prevented and permanent sealing of the lead and lead entry
points can be guaranteed. Lead ties are used for lead fixing.
The spacing of the lead bushings must be selected so that a torque wrench
can be used to tighten the lead bushings and cap nuts. .