![Motortech DetCon series Operating Manual Download Page 65](http://html1.mh-extra.com/html/motortech/detcon-series/detcon-series_operating-manual_1839330065.webp)
6 Wiring of the Device
Rev. 02/2019
65
6.6
Wiring of the Analog Outputs for Ignition Timing Reduction
4-20 mA
Output connector on the DetCon
+24 V DC supply voltage
Connection on the Ignition Controller
* 4–20 mA signal
Alternative
Output connector on the DetCon
Connection on the Ignition Controller
* 4–20 mA signal
0-5 V
Output connector on the DetCon
Connection on the Ignition Controller
* 0–5 V signal
The precise connection assignment on the ignition controller can be found in section
Input
Wiring – Ignition Timing & Safety Devices
in the operating manual for your MOTORTECH ignition
controller.