
84
Rev. 02/2019
9.1
Start-up
Before you start up the DetCon detonation controller, take note of the following:
–
Has the parameter file corresponding to the engine and the DetCon device type been loaded
to the device?
–
Have the detonation sensors been wired in accordance with the firing order of the engine?
–
Has the ignition sensor unit (ISU) or the camshaft sensor been wired correctly?
9.2
Start-up of the ATEX enclosure
The following points must be checked before initial operation:
–
The enclosures must be properly installed.
–
The enclosures must not be damaged, especially the gaskets.
–
There must be no foreign objects in the housing.
–
The terminal compartment must be clean.
–
The mounting and equipment screws must be firmly tightened.
–
The cable bushings must be firmly tightened.
–
All cables must be installed in the bushings according to the degree of protection.
–
Unused holes must be sealed with certified plugs.
The external protective conductor connection must be installed correctly and close to the
housing.
9.3
Shutdown
The device is shut down by disconnecting it from the power supply.
9 Operation
Summary of Contents for DetCon series
Page 1: ...DetCon Detonation Controller Operating Manual P N 01 30 002 Rev 02 2019...
Page 23: ...4 Product Description Rev 02 2019 23...
Page 24: ...4 Product Description 24 Rev 02 2019...
Page 25: ...4 Product Description Rev 02 2019 25...
Page 26: ...4 Product Description 26 Rev 02 2019...
Page 27: ...4 Product Description Rev 02 2019 27...
Page 37: ...4 Product Description Rev 02 2019 37 DetCon20 Dimensions...
Page 89: ......
Page 90: ......