![MOTO GUZZI California 1400 Instructions Manual Download Page 125](http://html1.mh-extra.com/html/moto-guzzi/california-1400/california-1400_instructions-manual_1838050125.webp)
2. Temperature signal
3. Power supply 5V
4. Signal
DIAGNOSTICS INSTRUMENT: PARAMETERS
Reference pressure Intake above sea level
•
Example value with key ON: 1009 mbar
•
Example value with engine on: 670 mbar
•
NOTE: pressure estimated by the control unit according to the throttle position
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING, CAREFULLY READ THE GENERAL TROU-
BLESHOOTING CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGINNING OF THE CHECK
AND CONTROL SECTION IN THE ELECTRICAL SYSTEM CHAPTER.
DIAGNOSTICS INSTRUMENT: ELECTRICAL ERRORS
P0105 cylinder air pressure sensor
•
shorted to positive / open circuit, shorted to negative.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 24. If the circuit is open,
shorted to negative: voltage equal to zero has been detected at PIN 24.
Troubleshooting
•
If shorted to positive: verify that the parameter of the front cylinder air Pressure Sensor on
the diagnostics instrument is approx. 1200 mbar; disconnect the sensor connector: if the
value does not vary, it means that the cable is shorted between the control unit connector
and the sensor connector: restore the cable harness; Replace the sensor if the value varies.
•
If the circuit is open, shorted to negative: check the Marelli control unit connector and the
sensor connector; if not OK, restore. If everything is OK, with key set to OFF, check if there
is continuity between the PIN 24 of the Marelli control unit and the sensor connector PIN 4:
if there is no continuity, restore the cable harness. If there is continuity, check the cable
ground insulation: if there is continuity to ground, restore the cable harness; if not, with key
set to ON check that the voltage on sensor connector PIN 3 is approx. 5 V: if not OK, set
the key to OFF and check continuity between the ENGINE connector PIN 51 and the sensor
connector PIN 3: if not OK, restore the cable harness; if OK, replace the control unit; if there
is 5V voltage at PIN 3, and with key set to ON, check the continuity to ground of the sensor
connector PIN 4: if not OK, restore the cable harness; if OK, replace the sensor.
DIAGNOSTICS INSTRUMENT: LOGIC ERRORS
P0107 air pressure sensor
•
signal not valid.
Error cause
California 1400
Electrical system
ELE SYS - 125
Summary of Contents for California 1400
Page 1: ...MMS California 1400 My12 B043157 California 1400...
Page 5: ...INDEX OF TOPICS CHARACTERISTICS CHAR...
Page 46: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS...
Page 53: ...INDEX OF TOPICS MAINTENANCE MAIN...
Page 64: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL...
Page 73: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS...
Page 163: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE...
Page 183: ...California 1400 Engine from vehicle ENG VE 183...
Page 184: ...INDEX OF TOPICS ENGINE ENG...
Page 187: ...Diagram key 1 Ball bearing 2 Circlip 3 Thickness 4 Pin California 1400 Engine ENG 187...
Page 280: ...INDEX OF TOPICS POWER SUPPLY P SUPP...
Page 291: ...INDEX OF TOPICS SUSPENSIONS SUSP...
Page 329: ...INDEX OF TOPICS CHASSIS CHAS...
Page 338: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS...
Page 365: ...INDEX OF TOPICS BODYWORK BODYW...