125
Rev. 1.1
2018/04
400-820-9661
M2DC Series Hardware Manual
P-28 (VC)
speed change
Data Range
Default
Unit
Data type
0.025 - 100
2
rps
DEC
The secondary speed for FC and FD moves.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 240
Where = is target velocity setting, Unit is rps (rev/sec) .
P-29 (JC)
Jog mode speed 1
Data Range
Default
Unit
Data type
0.025 - 100
2
rps
DEC
The first speed used in velocity mode. This only applies to control modes 15, 16, 17, and 18.
P-30 (JC)
Jog mode speed 2
Data Range
Default
Unit
Data type
0.025 - 100
10
rps
DEC
The second speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.
P-31 (JC)
Jog mode speed 3
Data Range
Default
Unit
Data type
0.025 - 100
20
rps
DEC
The third speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.
P-32 (JC)
Jog mode speed 4
Data Range
Default
Unit
Data type
0.025 - 100
25
rps
DEC
The fourth speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.
P-33 (JC)
Jog mode speed 5
Data Range
Default
Unit
Data type
0.025 - 100
30
rps
DEC
The fifth speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.
P-34 (JC)
Jog mode speed 6
Data Range
Default
Unit
Data type
0.025 - 100
35
rps
DEC
The sixth speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.
P-35 (JC)
Jog mode speed 7
Data Range
Default
Unit
Data type
0.025 - 100
40
rps
DEC
The seventh speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.