7.3.3.6 Torque Limit
In single-ended analog mode, analog input 2 (ANA2) can used to set motor’s output torque.
Parameter Settings
Parameter
Name
Data
Range
Default
value
Unit
Description
P-55 (AS)
Analog type
0~1
0
Analog input type
0: Single ended input 1: Differential input
P-62 (FA2)
Analog 2 function
setting
2~3
3
□
Analog input port 2 function setting:
2: Torque limit setting 3: Not in use
P-51 (AN)
Analog Torque
Gain
Based on
drive’s
output
ability
1
A
Sets correspondening torque output value
against 10VDC input voltage.
NOTE: When viewing or setting this value on the drive’s control panel (P-51 (AN)), refer to the following
calculation:
Drive display value=
x 100
where
is target torque output value
Setting Via Software