8.4 System Installation
CAUTION
Make sure that the machine nozzle orifice matches or is maximum 1.0 mm
(0.040 in.) smaller than the melt entrance of the Hot Runner system.
After the Hot Runner system is installed in the molding machine, make
sure to bleed all the air from the hydraulic lines or a high gate vestige could
occur.
CAUTION
CAUTION
For Fusion Series
®
Lite systems, the wiring and plumbing layout and
connections should be designed and planned by a tool shop before system
installation.
CAUTION
CAUTION
The F3000 and F4000 nozzles are drop-in systems. They must be installed
in a cold condition.
CAUTION
CAUTION
In systems that contain F3000 and/or F4000 nozzles along with F5000,
F6000, F7000, and F8000 nozzles, the manifold must be raised to half heat
condition before it is installed in the hot half.
CAUTION
7. Heat the manifold to 50% of the process temperature before installation.
8. Carefully install the system in the mold, ensuring that the manifold
remains level to avoid damage to the nozzle wiring.
Lower the system, and make sure that it is correctly seated.
8-3