6.8 Disassembly
WARNING
Ensure the lifting eyebolt, lifting chain and crane are rated to support the
weight of the
mold.
WARNING - HIGH VOLTAGE
Ensure that all power to the system is disconnected before starting the
disassembly procedure. Failure to do so may result in serious injury or
death.
WARNING - HOT SURFACES
Extreme heat. Avoid contact with heated surfaces. Use appropriate
protective clothing. Failure to do so can cause serious injury.
CAUTION
Do not use the linear servo drive to retract or extract the rod until the
system reaches the internal hard stop position or the actuator may be
permanently damaged.
Ensure that any cables or attachments do not become damaged during this
process. Damaged cables can cause a permanent failure of the motor.
CAUTION
1. Cool the system to room temperature, between 10°C and 40°C
(50°F and 104°F).
2. Disconnect the water hoses from the actuator and / or clamp plate.
6-12
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.